(208) 923-0166
Whirlpool · dryer · F codes and letters

Whirlpool dryer error codes and the part they are pointing at

Your Whirlpool dryer flashed F22 or AF and quit before the towels were dry. The code is a reading the board did not like, not a part number.

$99 to diagnose — folded into the repair once you say yesCODES Electric and gas WhirlpoolSAFE CHECKS and nothing riskier — the meter does the rest

Monday–Friday 7:30–5:30 · Saturday 8–1 · closed Sunday

Electric dryer with the top raised, heating element and blower wheel exposed, drill on the floor
Whirlpool dryer · Nampa
On the truck

The machine behind the code, and the other five

Whirlpool · dryer

Whirlpool dryers in Nampa, old and new

Electric dryer with the top raised, heating element and blower wheel exposed, drill on the floor
Whirlpool dryer error codes

Whirlpool dryers span two generations. The older Duet and Cabrio machines in the 1970s houses along Karcher Rd and Midway Rd have tumbled since the second owner moved in; the newer top-load pairs came with the builder packages in the subdivisions off Ustick Rd, Middleton Rd and Deer Flat Rd. Both report faults with an F number for the electronics and sensors, or a letter pair like AF, PF or L2 for airflow, power and voltage. Maytag and Amana machines use the same list. The code says which reading tripped. Whether the cause is a thermistor, a stuck key, a lost breaker leg or a duct full of lint takes a meter and a walk to the hood outside.

The valley gives these dryers a workout. Dust from the onion fields toward Parma and the feedlots south of Melba comes in on jeans and rides the exhaust until the duct behind the wall is half its size, and AF posts on a dryer with a good element and a bad vent. Windy afternoons blow the exhaust flap shut on the west side of a house in West Nampa. A commuter who starts the dryer before leaving for Boise finds PF on the panel after a storm knocked the power off for a minute. And an electric Whirlpool posting L2 in a Star garage is usually running on one leg of its 240-volt feed after a breaker half-tripped.

Whirlpool dryer codes in plain words

CodeWhat the display meansUsually behind itSafe to check firstWhat we do
PFPower failed while the dryer was running.A short outage or brownout, then a cord loose in the outlet, then a failing breaker.Press start to resume the cycle. If PF appears with no outage, push the cord fully into the outlet.We measure voltage at the outlet and the terminal block under load and check for a breaker or connection that drops out when the element kicks in.
F01The main control board failed its own check.A surge from a storm, then the board’s memory, then a shorted part the board drives.Cut the power at the breaker for a couple of minutes and restart the dryer.We test the board outputs and the parts it feeds, and replace the board only when it fails on clean power with nothing shorted downstream.
F02A key on the panel is stuck or the panel has failed.A button held down by a bottle or a lint brush, then a membrane key that stays closed, then the user interface board.Press each key once, then cut power for two minutes.We test each key on the panel and replace the user interface when one reads closed with nothing touching it.
F22The exhaust thermistor reads open.The thermistor on the blower housing, then its connector, then the harness to the board.Cut the power for two minutes and try a timed dry. F22 returning on a cold dryer is a part.We meter the thermistor against its chart at room temperature and replace it, or repair the harness when the sensor is good.
F23The exhaust thermistor reads shorted.The thermistor, then a pinched harness at the blower housing, then the board input.Two minutes off at the breaker, then a cool-down cycle. If it comes back, stop there.We check the thermistor and harness with a meter and replace the sensor or release the pinched wire.
F70The main board and the user interface stopped talking.A power blip, then a loose ribbon connector, then the user interface board, then the main board.Cut power for two minutes. Most F70 codes after a storm clear and stay cleared.We check the connection between the boards, meter the supply to the user interface, and replace the board that has gone quiet.
F28The moisture sensor circuit reads open.Fabric-softener film on the sensor bars, then a connector at the sensor, then the harness or board.Take a cloth with a little rubbing alcohol to the pair of metal strips at the front of the drum, then run a sensor-dry cycle.We meter the sensor bars and their circuit to the board, clean or replace the sensor, and repair the harness if it reads open.
F29The moisture sensor circuit reads shorted.A wet or corroded sensor connector, then a harness rubbed through, then the board.Run one timed-dry cycle instead of sensor dry and see whether the dryer heats normally.We meter the sensor circuit for a short, find the rubbed wire or wet connector, and replace the sensor or harness.
F30Airflow is restricted, or the inlet temperature is climbing too fast.A vent duct packed with lint and field dust, then a crushed flex hose behind the dryer, then the inlet thermistor.Lift out the lint screen, then walk around the house and check that the hood flap opens with the dryer running on air only.We check airflow out at the hood, clear or replace the flex hose, meter the inlet thermistor, and replace it if it reads out of range.
AFAirflow through the dryer is too low to dry safely.A vent duct blocked by lint, a bird nest or a frozen flap, then a blower wheel packed with lint, then a long duct run with too many elbows.Pull the dryer out a few inches and make sure the flex hose is not kinked or crushed against the wall.With the dryer running we read airflow at the hood outside, clean the blower housing, replace a crushed flex, and tell you if the duct through the attic needs a longer job.
L2The heater is not getting full voltage. One leg of the 240-volt feed is missing or weak.A double breaker with one half tripped, then a burned terminal at the outlet or cord, then the heater relay on the board.Look at the dryer breaker in the panel. If one half of the pair is off, switch both fully off and back on once. If it trips again, leave it.We measure both legs at the terminal block, inspect the cord and outlet for heat damage, and replace the cord, terminal block or board when the meter finds the drop.

Whirlpool dryer repair in Nampa, one code at a time

We pull the stored codes from the board with the key sequence for the model and write them down in order, because a PF followed by an F01 says surge, while an F22 logged for a month says sensor. Then we clear them and run the dryer through its service test, which cycles the motor, heater and sensors one at a time while we watch. A heat or airflow code sends us outside to the hood with the dryer running, since most of the AF and F30 calls between Nampa and Parma are a duct problem wearing a sensor’s name. After that the meter goes on the part the code names: the thermistor against its chart, the element for resistance, both legs of the feed under load.

Syringa is an independent Nampa shop. We are not Whirlpool’s dealer, and the invoice carries nothing but the repair. Should your dryer still be young enough for Whirlpool’s own coverage to apply, we say so before the $99 is spent and you decide. The truck stocks thermistors, thermal fuses, high-limit thermostats, heating elements, belts, rollers, idlers and cords for the Whirlpool, Maytag and Amana models that fill this county, which is why the bulk of these repairs finish on the first visit. Boards and gas valve assemblies are ordered and fitted on a second trip that is already inside the number you approved. One written price after the diagnostic, with the $99 counted inside it when you say yes.

Whirlpool dryer repair in Nampa and Canyon County gets one written number after the diagnostic, and approving that number means the $99 is part of it, not added to it. Written warranty on every invoice. Request Whirlpool dryer service →

Whirlpool dryer questions

My Whirlpool dryer in West Nampa shows AF. Is the dryer broken or the vent?

Usually the vent. AF means the dryer cannot move enough air, and in the 1970s houses along Karcher Rd the duct often takes a long route beneath the floor and has never been cleaned. We take an airflow reading at the hood outside and check the blower wheel. If the dryer moves air fine with the flex hose off, the duct is the job, not the machine.

What does L2 mean on my electric Whirlpool dryer in Star?

The heater is only getting part of its voltage. A 240-volt dryer runs on two legs, and if one is missing the drum turns but nothing heats. Check the double breaker for a half-tripped pair once. If it trips again, leave it off and call; a burned terminal at the outlet or cord is common and we meter both legs under load.

Why does my Whirlpool dryer post PF every time there is a thunderstorm in Melba?

PF only records that power dropped while the dryer was running, and on the rural lines around Melba a summer storm does that regularly. Press start and the cycle resumes. It is a repair only when PF appears on a calm day, which points at a loose cord, a tired breaker or a board relay, and that is what we test.

Can I clear a Whirlpool dryer F-code myself?

Cutting the power at the breaker for two minutes clears the display on most models. Whether the code stays gone depends on the cause: a stuck key or a storm surge usually does; a thermistor, moisture sensor or airflow code is back before the second load finishes. When it returns, a meter finds the part for $99, counted inside the repair if you approve one.

Do you work on Maytag and Amana dryers with the same codes as Whirlpool?

Yes. Maytag, Amana and the newer Kenmore dryers built by Whirlpool use the same boards, sensors and code list, and the same parts are on the truck. The diagnosis runs the same way in a Caldwell subdivision or a farmhouse outside Wilder: read the code, measure the airflow, meter the part, write one number.

More code lists

Clothes Dryer Repair in Nampa — the full page →

Request service

Whirlpool dryer showing a code: book the meter.

The phone is quicker; the form lands on the same desk. Both get you a text with a window, and until a technician has had a meter on the machine the only figure anyone quotes is $99.

Open the request form
  • Window texted to you; the technician will call if you would rather talk
  • $99 buys the meter reading and the diagnosis — no money before that
  • The repair as one written figure, $99 folded in
  • Warranty term printed on the invoice

Book the diagnostic

Dispatch texts back with a window for the truck. The meter reading is $99, and an approved repair absorbs that $99 into its total.

$99 for the diagnosis · part of the repair total once you approve · no mailing lists, no marketing texts.

How a visit runs

Four steps, and no step five on the invoice

1

Window

Ring the shop or fill in the form; dispatch answers with a window, and a text follows as the truck pulls off Davis Ave — first stops go to the Boise commuters, Saturday mornings to everyone else.

2

Meter

Measurements come before opinions: amps at the compressor, degrees on the shelf, ohms across the element. The failed part gets its everyday name from the technician, who then writes the repair as a single figure, $99 folded in.

3

Part

The shelves on the truck hold what this valley wears out — inlet valves, defrost heaters, heating elements, igniters, drain pumps, rollers. When something must be ordered, the return trip happens on our calendar and the figure you approved stands.

4

Proof

The machine runs a whole cycle while you watch, panels and floor go back the way they were, and the invoice that reaches your email carries the warranty term.

Whirlpool dryer error code: one visit, one written number.

$99 puts a meter on the machine. The repair goes on the ticket as one figure with that $99 inside it, the part is usually riding in the truck, and the invoice states the warranty term. Parma pays what Davis Ave pays.

FORMRequest service